China Custom High Quality CHINAMFG Brand 45kw 55kw 8bar Electric Screw Air Compressor air compressor parts

Product Description

Refrigerated Compressed Air Dryer (Built-In Pre-Cooler)

Detailed Photos

Principle of working :
The amount of water vapor in the air compression by compressed air temperature determined: in case of compressed air pressure is basically the same, reduce the temperature of the air compressed compression to reduce the amount of water vapor in the air, and the excess water vapor will condense into liquid.
Freezing dryer is according to the corresponding relationship between the saturation water vapor pressure and temperature, use refrigeration device makes the compressed air is cooled to a certain dew point temperature, precipitation containing water, through the steam water separator and electric drainage device will discharge water, so that the compressed air can be dry.
 

Product Parameters

 

     
Model
 
Air Capacity
(Nm3/min)
Voltage
(V)
Fan Power
(W)
Air connector dia Net weight
(Kg)
Lenghth
(mm)
Wideth
(mm)
Height
(mm)
Air flow 
(Nm3/n)
SDLF-0.5HT 0.65 220 80 G1″ 54 400 560 730 820
SDLF-1HT 1.2 220 80 G1″ 57 400 560 730 820
SDLF-2HT 2.5 220 100 G1″ 66 520 640 890 1640
SDLF-3HT 3.6 220 135 G1″ 79 520 640 890 2670
SDLF-4.5HT 5.0 220 250 G1-1/2″ 86 540 700 1000 4650
SDLF-6HT 6.8 220 250 G1-1/2″ 90 540 700 1000 4650
SDLF-8HT 8.5 220 270 G2″ 99 610 900 1070 5700
SDLF-10HT 10.9 380/220 260 G2″ 113 610 900 1070 5700
SDLF-12HT 12.8 380/200 260 G2″ 113 610 900 1070 5700

Note: The above models use plate/plate-fin heat exchangers.

Company Profile

 

Certifications

 

Packaging & Shipping

 

FAQ

 

  /* March 10, 2571 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

After-sales Service: Ok
Warranty: 15 Months
Flow: Cross Flow
Material Status: Bulk
Drying Medium: Air
Structure: All Kinds
Samples:
US$ 400/Piece
1 Piece(Min.Order)

|
Request Sample

Customization:
Available

|

air compressor

How Does Variable Speed Control Work in Screw Compressors?

Variable speed control in screw compressors is a technology that allows the compressor’s rotational speed to be adjusted according to the compressed air or gas demand. This control method offers several benefits in terms of energy efficiency and system performance. Here’s a detailed explanation:

Variable speed control, also known as variable frequency drive (VFD) or inverter control, works by adjusting the speed of the compressor’s drive motor. The drive motor is typically an electric motor that powers the rotation of the compressor’s screw rotors.

The key components and operation of variable speed control in screw compressors are as follows:

  • 1. Drive Motor: The drive motor is connected to the compressor’s screw rotors and provides the rotational power required for compression. It is an electric motor capable of operating at variable speeds.
  • 2. Inverter or Variable Frequency Drive (VFD): The inverter or VFD is an electronic device that controls the speed of the drive motor. It converts the incoming electrical power into adjustable frequency and voltage, allowing precise control of the motor’s rotational speed.
  • 3. Control System: The control system of the screw compressor monitors and adjusts the speed of the drive motor based on the compressed air or gas demand. It receives input signals from sensors that measure parameters such as pressure, flow rate, or system demand, and sends corresponding signals to the inverter or VFD to regulate the motor speed.
  • 4. Speed Adjustment: When the demand for compressed air or gas decreases, the control system reduces the motor speed by decreasing the frequency and voltage supplied by the inverter or VFD. This results in a lower rotational speed of the screw rotors, reducing the compression capacity and power consumption of the compressor.
  • 5. Energy Efficiency: Variable speed control allows the compressor to match the output to the actual demand, avoiding energy wastage associated with constant-speed compressors. By operating at lower speeds during periods of lower demand, energy consumption can be significantly reduced. This energy-saving capability is particularly advantageous in applications with varying air or gas requirements.
  • 6. Smooth Operation: Variable speed control enables smooth and gradual motor acceleration and deceleration, minimizing mechanical stress on the compressor components and reducing the likelihood of sudden pressure surges or system shutdowns.
  • 7. System Stability: By adjusting the compressor’s speed to match the demand, variable speed control helps maintain stable system pressure and prevents excessive cycling of the compressor. This contributes to improved system performance and longevity.

It’s worth noting that variable speed control is more commonly found in larger screw compressors used in industrial and commercial applications. Smaller screw compressors may utilize fixed-speed motors due to cost considerations or simpler system requirements.

Overall, variable speed control in screw compressors offers precise capacity modulation, improved energy efficiency, enhanced system stability, and reduced maintenance requirements, making it a preferred choice in many applications where compressed air or gas demand fluctuates.

air compressor

Can Screw Compressors Be Used for Medical Air Supply?

Yes, screw compressors can be used for medical air supply. Here’s a detailed explanation:

Screw compressors are commonly employed in various applications, including medical air supply systems. Medical air is a critical utility in healthcare facilities, used for various purposes such as respiratory therapy, anesthesia, and surgical tools. Here are some key points to consider:

1. Reliability and Efficiency:

Screw compressors are known for their reliability and efficiency. They can provide a continuous and reliable source of compressed air, ensuring a stable supply for medical applications. The rotary screw design allows for smooth and efficient compression, minimizing energy consumption and maximizing system performance.

2. Oil-Free Operation:

In medical applications, it is crucial to ensure the purity of the compressed air. Screw compressors can be designed and certified to provide oil-free air, eliminating the risk of oil contamination in the medical air supply. Oil-free screw compressors incorporate specialized sealing systems and filtration to prevent oil carryover, making them suitable for medical air applications.

3. Air Quality Standards:

Medical air must meet specific air quality standards to ensure patient safety and treatment effectiveness. Standards such as the European Pharmacopoeia (Ph. Eur.) or the United States Pharmacopeia (USP) define the required purity levels for medical air, including limits on particulate matter, moisture content, and microbial contamination. Screw compressors can be equipped with appropriate filtration and purification systems to meet these standards.

4. Integrated Drying and Filtration:

Some screw compressors designed for medical air applications incorporate integrated drying and filtration systems. These systems remove moisture and contaminants from the compressed air, ensuring it meets the required quality standards. Integrated drying systems can include refrigerated dryers, desiccant dryers, or membrane dryers, depending on the specific needs of the medical air supply system.

5. Redundancy and Backup Systems:

Medical air supply systems often require a high level of reliability and continuity. Screw compressors can be configured with redundancy and backup systems to ensure uninterrupted supply. Multiple compressors can be installed in parallel, with automatic switching mechanisms to maintain supply in case of a compressor failure or maintenance activities.

6. Monitoring and Alarms:

Modern screw compressors used in medical air supply systems often feature advanced monitoring capabilities. They can continuously monitor and record key parameters such as pressure, temperature, and system performance. Alarms and alerts can be configured to notify operators or maintenance personnel in case of abnormal conditions or potential issues with the compressor.

7. Compliance with Standards and Regulations:

When using screw compressors for medical air supply, it is essential to comply with relevant standards and regulations. These may include medical device regulations, electrical safety standards, and guidelines specific to medical gas systems. Compliance ensures that the medical air supply system meets the necessary safety and quality requirements.

In summary, screw compressors can be used for medical air supply, providing reliable and efficient compressed air for various medical applications. With their reliability, oil-free operation, adherence to air quality standards, integrated drying and filtration capabilities, and the ability to incorporate redundancy and monitoring features, screw compressors are well-suited for medical air supply systems in healthcare facilities.

air compressor

What Are the Maintenance Requirements for Screw Compressors?

Screw compressors require regular maintenance to ensure optimal performance, reliability, and longevity. Here’s a detailed overview of the maintenance requirements for screw compressors:

  • 1. Lubrication: Screw compressors rely on proper lubrication to reduce friction, minimize wear, and maintain efficient operation. Regular lubrication of the rotor bearings, seals, and other moving parts is essential. The type and frequency of lubrication may vary depending on the compressor’s design and manufacturer’s recommendations.
  • 2. Filter Replacement: Screw compressors have intake filters that prevent dust, debris, and contaminants from entering the compression chamber. These filters need to be inspected regularly and replaced or cleaned as necessary to ensure unrestricted airflow and prevent damage to the compressor components.
  • 3. Cooling System Maintenance: Screw compressors may have cooling systems, such as air or water coolers, to dissipate heat generated during compression. The cooling system should be inspected periodically, and any blockages or leaks should be addressed promptly to maintain optimal cooling efficiency.
  • 4. Inspection of Belts and Couplings: If the screw compressor is belt-driven or connected through couplings, regular inspection of belts, pulleys, and couplings is necessary. Worn or damaged belts should be replaced, and couplings should be checked for alignment and tightness to ensure smooth power transmission.
  • 5. Cleaning of Heat Exchangers: Heat exchangers in screw compressors, such as intercoolers and aftercoolers, can accumulate dirt, scale, and other deposits over time. Regular cleaning of these heat exchangers is important to maintain their heat transfer efficiency and prevent overheating of the compressed air or gas.
  • 6. Inspection of Seals and Gaskets: The seals and gaskets in a screw compressor play a critical role in maintaining proper compression and preventing air or gas leakage. Regular inspection of these components is necessary to detect any signs of wear, damage, or leakage. Faulty seals or gaskets should be replaced promptly to maintain the compressor’s efficiency.
  • 7. Regular Performance Testing: Periodic performance testing of screw compressors is recommended to assess their operating parameters, such as discharge pressure, flow rate, and power consumption. This helps identify any deviations from the expected performance and allows for adjustments or repairs as needed.

It’s important to note that the specific maintenance requirements for screw compressors may vary depending on the compressor’s design, manufacturer’s recommendations, operating conditions, and usage. Consulting the compressor’s manual and following the manufacturer’s guidelines is crucial for maintaining the compressor effectively and ensuring its reliable operation over time.

China Custom High Quality CHINAMFG Brand 45kw 55kw 8bar Electric Screw Air Compressor   air compressor partsChina Custom High Quality CHINAMFG Brand 45kw 55kw 8bar Electric Screw Air Compressor   air compressor parts
editor by CX 2024-02-19

Leave a Reply